Audiokinetic's Community Q&A is the forum where users can ask and answer questions within the Wwise and Strata communities. If you would like to get an answer from Audiokinetic's Technical support team, make sure you use the Support Tickets page.

0 votes

I used to be able to connect a control surface and bind game parameters in Wwise using the method found Here

I went back to an old project using the latest version of Wwise and I get the status "not active: object does not support property" for all my simulation value bindings. (Control+Shift+Q to view this window)

You can still select simulation value by clicking on green highlighted RTPCs in the transport with "learn", but the option is no longer available under [>>] Games Syncs > Game Parameter > Simulation Value

Does anyone know if this feature is still available? I thought it was a very useful thing to have. Here is a picture.

 
Thanks for any information!
in General Discussion by Stefan K. (100 points)

1 Answer

0 votes
This is a technical limitation of Wwise 2016.2. It will be fixed as part of 2017.1. We are sorry for the inconveniences.
by Bernard R. (Audiokinetic) (35.8k points)
Thanks for the information!
...